0511-80780956
  • News
  • Company News
  • Industry News
  • Qualification Certificate
  • Customer case
  • Case
  • Contact us
  • Contact us
  • Online consultation
  • Complaint suggestion
  • Product
  • Magnetic Field Cancelling System
  • Tokkyokiki Magnetic Field Cancelling System
  • Vibration Isolation System
  • Tokkyokiki Active Vibration Isolation System
  • Mul Build HATA-Holder System
  • Mul Build HATA-Holder System
  • PIE plasma cleaners
  • EM-KLEEN
  • Tergeo-EM
  • Nexperion SentineL
  • Nexperion SentineL
  • WET-SEM
  • SEM Sample Room QX-102
  • SEM Sample Room QX-202
  • SEM Sample Room QX-302
  • SEM Sample Room Accessory
  • Temassist-Towards Automatic TEM solutions
  • Temassist-Towards Automatic TEM solutions
  • LaB6 Filament
  • Denka LaB6
  • Kimball Physics LaB6
  • Compressors
  • JUN Air
  • Chiller
  • LabTech HF500 split Chiller
  • Vacuum System
  • Edwards Ion pump
  • Pfeiffer Turbomolecular Pumps
  • Pfeiffer Vacuum gauge
  • Pumping Station
  • Nanoimprint Machine
  • THU400 Nanoimprint Machine
  • THU600 Nanoimprint Machine
  • THU800 Nanoimprint Machine
  • High-vacuum Optical Platform for cryo-CLEM
  • HOPE V1
  • Quick Freeze Substitution Equipment
  • QFSE
  • 请在后台添加自定义HTML标签:ft_contact
    CryoMatrix-Carbon Film
    Location: Home / Product / CryoMatrix-Carbon Film
    CryoMatrix-Carbon film

    Product Details


    CryoMatrix® holey grid is a supporting film with regularly arranged micro holes, which is common used for electron microscopy imaging. It has a wide application in cryo-electron microscopy study, especially for the high-throughput automated data collection. CryoMatrix®  support film is divided into two series, carbon film series and amorphous alloy film series. It is flat with smooth edges of holes, unfragile and well conductive without organic contamination. CryoMatrix®  is suitable for cryo-electron microscopy high-resolution imaging. CryoMatrix® keeps the good performance in a long life with vacuum package.


    Instructions for use


    Firstly, place the CryoMatrix®  support film in a glow discharge instrument, such as Gatan Solarus or plasma cleaner to make it hydrophilic. The hydrophilic processing parameters are exampled as H2/O2 or O2/Ar, 30 s. Secondly, drop 3.0ul sample solution onto the CryoMatrix® support film, blot 3~4 s with filter paper Whatman (597), and then quickly throw into the liquid ethane cooled by liquid nitrogen. Finally, transfer the freezed grid into TEM or sample container.


    Product specification



    Application example




      Apoferritin frozen on CryoMatrix®  supporting film: a) LM imaging on C film; b) HM on C film; c) 3D reconstruction frozen on C film; d) LM imaging on on NiTi film; e) HM on NiTi film; f) 3D reconstruction frozen on NiTi film;


    Related products
    Copyright © 2002-2011 镇江千赢国际qy142电子科技有限公司 版权所有 ICP:苏ICP备15054343号